Comparison of myocardial fractional flow reserve and intravascular ultrasound for the assessment of slotted-tube stents
dc.contributor.author | Katritsis, D. G. | en |
dc.contributor.author | Ioannidis, J. P. | en |
dc.contributor.author | Korovesis, S. | en |
dc.contributor.author | Giazitzoglou, E. | en |
dc.contributor.author | Parissis, J. | en |
dc.contributor.author | Kalivas, P. | en |
dc.contributor.author | Webb-Peploe, M. M. | en |
dc.date.accessioned | 2015-11-24T19:28:30Z | |
dc.date.available | 2015-11-24T19:28:30Z | |
dc.identifier.issn | 1522-1946 | - |
dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/22903 | |
dc.rights | Default Licence | - |
dc.subject | Aged | en |
dc.subject | Angina Pectoris/diagnosis/physiopathology/*therapy | en |
dc.subject | Angioplasty, Balloon, Coronary/*instrumentation | en |
dc.subject | Collateral Circulation/physiology | en |
dc.subject | Coronary Angiography | en |
dc.subject | *Coronary Circulation/*physiology | en |
dc.subject | Female | en |
dc.subject | Graft Occlusion, Vascular/*diagnosis/physiopathology | en |
dc.subject | Humans | en |
dc.subject | Male | en |
dc.subject | Middle Aged | en |
dc.subject | Predictive Value of Tests | en |
dc.subject | Prosthesis Failure | en |
dc.subject | ROC Curve | en |
dc.subject | Regional Blood Flow/physiology | en |
dc.subject | *Stents | en |
dc.subject | Treatment Outcome | en |
dc.subject | *Ultrasonography, Interventional | en |
dc.title | Comparison of myocardial fractional flow reserve and intravascular ultrasound for the assessment of slotted-tube stents | en |
heal.abstract | Intravascular ultrasound (IVUS) and myocardial fractional flow reserve (FFR) have been reported to provide similar results for assessment of coil stent deployment. Their relative value in slotted-tube stents has not been investigated. Fourteen patients subjected to coronary angioplasty and IVUS-guided elective stenting with a slotted-tube stent underwent IVUS assessment and FFR measurement following stent implantation at inflation pressures of 12 and 18 atm. FFR values (mean +/- SD) preangioplasty, postangioplasty, and poststenting at 12 atm and 18 atm, were 0.58 +/- 0.07, 0.83 +/- 0.05, 0.94 +/- 0.02, and 0.94 +/- 0.02, respectively. After inflation at 12 atm, the area under the receiver operating characteristic (ROC) curve for the concordance of IVUS and FFR measurements was 0.89 (P = 0.02). Six patients had either an abnormal IVUS (n = 2) or FFR < 0.94 (n = 1) or both abnormal IVUS and FFR < 0.94 (n = 3) after the first inflation and had a second inflation at 18 atm. The area under the ROC curve for the concordance between IVUS and FFR final measurements was 0.855 (P = 0.10). Perfect concordance between IVUS and FFR was seen only for FFR values less than 0.91 or larger than 0.94. Overall, IVUS and FFR have substantial concordance with respect to slotted-tube stent deployment. However, FFR values between 0.91 and 0.94 after inflation are difficult to interpret. | en |
heal.access | campus | - |
heal.fullTextAvailability | TRUE | - |
heal.identifier.primary | 10.1002/ccd.1074 | - |
heal.identifier.secondary | http://www.ncbi.nlm.nih.gov/pubmed/11246245 | - |
heal.identifier.secondary | http://onlinelibrary.wiley.com/store/10.1002/ccd.1074/asset/1074_ftp.pdf?v=1&t=h0jervri&s=eb299356143d4ad510989c25c909166c55b1d0e9 | - |
heal.journalName | Catheter Cardiovasc Interv | en |
heal.journalType | peer-reviewed | - |
heal.language | en | - |
heal.publicationDate | 2001 | - |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών Υγείας. Τμήμα Ιατρικής | el |
heal.type | journalArticle | - |
heal.type.el | Άρθρο Περιοδικού | el |
heal.type.en | Journal article | en |
Αρχεία
Φάκελος/Πακέτο αδειών
1 - 1 of 1
Φόρτωση...
- Ονομα:
- license.txt
- Μέγεθος:
- 1.74 KB
- Μορφότυπο:
- Item-specific license agreed upon to submission
- Περιγραφή: