Effect of high-dose electron beam irradiation on the migration of DOA and ATBC plasticizers from food-grade PVC and PVDC/PVC films, respectively, into olive oil
Φόρτωση...
Ημερομηνία
Συγγραφείς
Goulas, A. E.
Riganakos, K. A.
Ehlermann, D. A. E.
Demertzis, P. G.
Kontominas, M. G.
Τίτλος Εφημερίδας
Περιοδικό ISSN
Τίτλος τόμου
Εκδότης
Περίληψη
Τύπος
Είδος δημοσίευσης σε συνέδριο
Είδος περιοδικού
peer reviewed
Είδος εκπαιδευτικού υλικού
Όνομα συνεδρίου
Όνομα περιοδικού
Journal of Food Protection
Όνομα βιβλίου
Σειρά βιβλίου
Έκδοση βιβλίου
Συμπληρωματικός/δευτερεύων τίτλος
Περιγραφή
The effect of high-dose irradiation on the migration of dioctyl adipate (DOA) and acetyI tributyl citrate (ATBC) plasticizers from food-grade poly(vinyl chloride) (PVC) and poly(vinylidene chloride/vinyl chloride) (PVDC/PVC) copolymer (Saran) films, respectively, into olive oil was studied. The results showed a significantly higher amount of DOA migrated into olive oil from irradiated versus nonirradiated samples. This difference was more noticeable in oil samples collected during initial periods of contact. The amount of DOA migrating into olive oil was lower fur samples irradiated at a dose of 20 kGy in comparison with samples irradiated at a dose of 50 kGy. At a sampling lime of 1 h the amount of DOA that migrated into olive oil was 93.9 mg/liter, 141.5 mg/liter, and 183.4 mg/liter for nonirradiated samples, 20-kGy irradiated samples, and 50-kGy irradiated samples, respectively. After 288 hr (13 daps) of oil-film contact the respective amounts were 390.8 mg/liter, 409.2 mg/liter, and 430.1 mg/liter. There were no statistically significant differences in migrating amount of ATBC between nonirradiated samples and samples irradiated at a dose of 20 kGy, while in samples irradiated at a dose of 50 kGy the migration of ATBC was increased. After I h of oil-film contact no detectable amounts of ATBC had migrated. After 288 h of contact the amounts of ATBC that migrated into olive oil were 3.59 mg/liter, 3.56 mg/liter, and 4.12 mg/liter for nonirradiated samples, 20-kGy irradiated samples, and 50-kGy irradiated samples, respectively. It is suggested that plasticized PVC should not be used in direct contact with high-fat foodstuffs with or without irradiation treatment.
Περιγραφή
Λέξεις-κλειδιά
ionizing-radiation, packaging materials, gamma-radiation, dioctyladipate, simulants, phthalate, products
Θεματική κατηγορία
Παραπομπή
Σύνδεσμος
<Go to ISI>://000074169400015
Γλώσσα
en
Εκδίδον τμήμα/τομέας
Όνομα επιβλέποντος
Εξεταστική επιτροπή
Γενική Περιγραφή / Σχόλια
Ίδρυμα και Σχολή/Τμήμα του υποβάλλοντος
Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας