Development of 1-(2-pyridylazo)-2-naphthol-modified polymeric membranes for the effective batch pre-concentration and determination of zinc traces with flame atomic absorption spectrometry

dc.contributor.authorGiokas, D. L.en
dc.contributor.authorPaleologos, E. K.en
dc.contributor.authorProdromidis, M. I.en
dc.contributor.authorKarayannis, M. I.en
dc.date.accessioned2015-11-24T16:55:53Z
dc.date.available2015-11-24T16:55:53Z
dc.identifier.issn0039-9140-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/10366
dc.rightsDefault Licence-
dc.subject1-(2-pyridylazo)-2-naphthol-modified cellulose acetate membranesen
dc.subjectpre-concentrationen
dc.subjectzinc determinationen
dc.subjectseawater and wastewateren
dc.subjectflame atomic absorption spectrometryen
dc.subjectautomated online preconcentrationen
dc.subjectplasma-mass spectrometryen
dc.subjectwater samplesen
dc.subjectsea-wateren
dc.subjectextractionen
dc.subjectadsorptionen
dc.subjectspeciationen
dc.subjectseparationen
dc.subjectiron(ii)en
dc.subjectchromiumen
dc.titleDevelopment of 1-(2-pyridylazo)-2-naphthol-modified polymeric membranes for the effective batch pre-concentration and determination of zinc traces with flame atomic absorption spectrometryen
heal.abstractThe development of 1-(2-pyridylazo)-2-naphthol (PAN)-modified polymeric membranes for the effective batch pre-concentration and determination of zinc traces with flame atomic absorption spectrometry (FAAS) is described. The method is based on the chemical bonding of the metal species with a suitable ligand, which has been immobilized into a water-insoluble cellulose acetate (CA) membrane followed by simple rinsing of the chelating agent-metal complex with an acidified methanolic solution. The latter is directly aspirated to the nebulizer of a FAA spectrophotometer without any other treatment. As an analytical demonstration, trace concentrations of Zn(II) were successfully detected in real samples, such as seawater, river and take water, wastewater as well as in a reference material, without any laborious and time-consuming treatment. Several working parameters were investigated. A pre-concentration factor of 100 was achieved by simple immersing of a circular piece of the CA-PAN membrane (0.6 cm diameter) in the tested samples for 30 min at room temperature. The analytical curve was rectilinear up to 30 mug l(-1) zinc with detection limit of 0.7 mug l(-1), a quantitation limit of 2.0 mug l(-1) and a relative standard deviation lower than 2%. (C) 2002 Elsevier Science B.V. All rights reserved.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.primaryDoi 10.1016/S0039-9140(01)00572-0-
heal.identifier.secondary<Go to ISI>://000174751800013-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0039914001005720/1-s2.0-S0039914001005720-main.pdf?_tid=cccee7da-349c-11e3-b3b3-00000aacb360&acdnat=1381733560_ad437f6d53fbb95cefd54717d07a991f-
heal.journalNameTalantaen
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate2002-
heal.publisherElsevieren
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: