HILIC separation and quantitation of water-soluble vitamins using diol column
dc.contributor.author | Karatapanis, A. E. | en |
dc.contributor.author | Flamegos, Y. C. | en |
dc.contributor.author | Stalikas, C. D. | en |
dc.date.accessioned | 2015-11-24T16:39:00Z | |
dc.date.available | 2015-11-24T16:39:00Z | |
dc.identifier.issn | 1615-9306 | - |
dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/8112 | |
dc.rights | Default Licence | - |
dc.subject | hydrophilic interaction liquid-chromatography | en |
dc.subject | separation | en |
dc.subject | quantitation | en |
dc.subject | water-soluble vitamins | en |
dc.subject | performance liquid-chromatography | en |
dc.subject | hydrophilic-interaction chromatography | en |
dc.subject | fortified food-products | en |
dc.subject | solid-phase extraction | en |
dc.subject | capillary-electrophoresis | en |
dc.subject | fluorescence detection | en |
dc.subject | dietary-supplements | en |
dc.subject | ionizable compounds | en |
dc.subject | acid-extraction | en |
dc.subject | polar compounds | en |
dc.title | HILIC separation and quantitation of water-soluble vitamins using diol column | en |
heal.abstract | Hydrophilic interaction liquid-chromatography (HILIC) in conjunction with diode array detection has been applied for the separation of selected-water-soluble vitamins using an end-capped HILIC-diol column. Vitamins with significant biological importance, such as thiamine (B(1)), riboflavin (B(2)), nicotinic acid (B(3)), nicotinamide (B(3)), pyridoxine (B(6)), folic acid (B(9)), cyanocobalamin (B(12)) and ascorbic acid (vitamin C) were simultaneously separated. Chromatographic conditions including type and percentage of organic modifier in the mobile phase, pH, type and concentration of buffer salt and flow rate were investigated. ACN was shown to offer superior separation for the compounds tested as compared to methanol, isopropanol and THE Isocratic separation and analysis were achieved for six vitamins (B(1), B(2), nicotinic acid/nicotinamide, B(6) and C) at ACN-H(2)O 90:10, containing ammonium acetate 10 mM, triethylamine 20 mM, pH 5.0, using a flow rate of 0.8 mL/min, while a gradient was necessary to resolve a mixture of all eight water-soluble vitamins. The HILIC method was validated and successfully applied to the analysis of a pharmaceutical formulation and an energy drink negating the need for time consuming clean-up steps. | en |
heal.access | campus | - |
heal.fullTextAvailability | TRUE | - |
heal.identifier.primary | DOI 10.1002/jssc.200800525 | - |
heal.identifier.secondary | <Go to ISI>://000265123100001 | - |
heal.identifier.secondary | http://onlinelibrary.wiley.com/store/10.1002/jssc.200800525/asset/909_ftp.pdf?v=1&t=h0e1zhku&s=8ba81aef2a3092c0c5cacb28ea46ee66232c57fe | - |
heal.journalName | J Sep Sci | en |
heal.journalType | peer reviewed | - |
heal.language | en | - |
heal.publicationDate | 2009 | - |
heal.publisher | WILEY-VCH Verlag | en |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας | el |
heal.type | journalArticle | - |
heal.type.el | Άρθρο Περιοδικού | el |
heal.type.en | Journal article | en |
Αρχεία
Φάκελος/Πακέτο αδειών
1 - 1 of 1
Φόρτωση...
- Ονομα:
- license.txt
- Μέγεθος:
- 1.74 KB
- Μορφότυπο:
- Item-specific license agreed upon to submission
- Περιγραφή: