Simultaneous spectrofluorimetric determination of selenium(IV) and (VI) by flow injection analysis

Φόρτωση...
Μικρογραφία εικόνας

Ημερομηνία

Συγγραφείς

Ahmed, M. J.
Stalikas, C. D.
Veltsistas, P. G.
TzouwaraKarayanni, S. M.
Karayannis, M. I.

Τίτλος Εφημερίδας

Περιοδικό ISSN

Τίτλος τόμου

Εκδότης

Royal Society of Chemistry

Περίληψη

Τύπος

Είδος δημοσίευσης σε συνέδριο

Είδος περιοδικού

peer reviewed

Είδος εκπαιδευτικού υλικού

Όνομα συνεδρίου

Όνομα περιοδικού

Analyst

Όνομα βιβλίου

Σειρά βιβλίου

Έκδοση βιβλίου

Συμπληρωματικός/δευτερεύων τίτλος

Περιγραφή

A simple, sensitive, highly selective, automatic spectrofluorimetric method for the simultaneous determination of selenium(IV) and (VI) as selenite-selenate by flow injection analysis (FIA) has been developed. The method is based on the selective oxidation of the non-fluorescent reagent 2-(alpha-pyridyl)thioquinaldinamide (PTQA) in acidic solution (1.5-3.0 M H2SO4) by Se-IV to give an intensely fluorescent oxidation product (lambda(ex) = 350 nm; lambda(em) = 500 nm). Selenium(VI) is reduced on-line to Se-IV, in a reduction coil installed in a photo-reactor, which is then treated with PTQA and the fluorescence due to the sum of Se-IV and Se-VI is measured; Se-VI is determined from the difference in fluorescence values. Various analytical parameters, such as effect of acidity, flow rate, sample size, dispersion coefficient, temperature, reagent concentration and interfering species were studied. The photo-reduction conditions were optimized, with an FIA procedure, for Se-VI on the basis of its reduction efficiency. The calibration graphs were rectilinear for 0.1-2.4 mu g ml(-1) of Se-VI and 10 ng ml(-1)-2.2 mu g ml(-1) of Se-IV, respectively. The method was applied to the determination of Se in several Standard Reference Materials (alloy, sediments and tea), as well as in some environmental waters (tap and surface water), food samples (flour and egg), a biological sample (human hair), soil sample and in synthetic mixtures. Up to 25 samples per hour can be analysed with an RSD approximate to 0.1-2%.

Περιγραφή

Λέξεις-κλειδιά

flow injection, spectrofluorimetry, selenium speciation, 2-(alpha-pyridyl)thioquinaldinamide, on-line photo-reduction, environmental, biological, soil samples, atomic-absorption spectrometry, speciation, generation, sediments, reduction, matrices, waters, system, soils, foods

Θεματική κατηγορία

Παραπομπή

Σύνδεσμος

<Go to ISI>://A1997WP43900004
http://pubs.rsc.org/en/content/articlepdf/1997/an/a606357h

Γλώσσα

en

Εκδίδον τμήμα/τομέας

Όνομα επιβλέποντος

Εξεταστική επιτροπή

Γενική Περιγραφή / Σχόλια

Ίδρυμα και Σχολή/Τμήμα του υποβάλλοντος

Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας

Πίνακας περιεχομένων

Χορηγός

Βιβλιογραφική αναφορά

Ονόματα συντελεστών

Αριθμός σελίδων

Λεπτομέρειες μαθήματος

item.page.endorsement

item.page.review

item.page.supplemented

item.page.referenced