Transosseous application of low-intensity ultrasound for the enhancement and monitoring of fracture healing process in a sheep osteotomy model

Φόρτωση...
Μικρογραφία εικόνας

Ημερομηνία

Συγγραφείς

Malizos, K. N.
Papachristos, A. A.
Protopappas, V. C.
Fotiadis, D. I.

Τίτλος Εφημερίδας

Περιοδικό ISSN

Τίτλος τόμου

Εκδότης

Elsevier

Περίληψη

Τύπος

Είδος δημοσίευσης σε συνέδριο

Είδος περιοδικού

peer reviewed

Είδος εκπαιδευτικού υλικού

Όνομα συνεδρίου

Όνομα περιοδικού

Bone

Όνομα βιβλίου

Σειρά βιβλίου

Έκδοση βιβλίου

Συμπληρωματικός/δευτερεύων τίτλος

Περιγραφή

The purpose of this study is twofold: (a) to investigate the application of transosseous low-intensity pulsed ultrasound (LiUS) on the enhancement of fracture healing and (b) to demonstrate the ability of transosseous ultrasound propagation to monitor the healing process. A midshaft tibial osteotomy model was used on 40 skeletally mature sheep, and an external fixator was applied to maintain the reduction and stabilization of the osteotomy. Two ultrasound transducers were implanted into the fracture site in contact with the bone. For investigating the efficacy of LiUS, the animals were randomly divided in two equal groups: the treatment group and the control group. The LiUS-treated animals received 200-mu s bursts of 1-MHz sine waves with a pulse repetition rate of 1 kHz and average intensity of 30 mW/cm(2), for 20 min daily. For monitoring purposes, an ultrasound dataset was constructed consisting of serial ultrasound measurements obtained from healing bones. Animals' sacrifice took place on the 100th postoperative day. The effect of LiUS on fracture healing was evaluated using radiographs, destructive three-point bending testing and quantitative CT-based bone mineral density (BMD) measurements. Survival analysis using Kaplan-Meier curves showed significantly higher probability of radiographic healing for the animals in the treatment group (P = 0.009). Statistical significance was also observed for callus BMD (P = 0.003, Wilcoxon nonparametric test), the breaking load (P = 0.001), extrinsic stiffness (P = 0.019), Young's modulus (P = 0.043) and ultimate strength (P = 0.051) in favor of the LiUS-treated limbs. Analysis of the obtained ultrasonic measurements showed that the propagation velocity across healing bones constitutes a significant feature able to early distinguish between healed and nonhealed bones (area under ROC curve was 0.810 and 0.841 on the 80th and 100th post-operative days, respectively). Both the LiUS application and the ultrasonic measurements are supported by an integrated telemedicine system which also incorporates an ultrasound wearable device and a patient management system. (c) 2005 Elsevier Inc. All rights reserved.

Περιγραφή

Λέξεις-κλειδιά

low-intensity pulsed ultrasound, acceleration of fracture healing, monitoring of fracture healing, animal fracture model, wearable medical devices, telemedicine, pulsed ultrasound, computed-tomography, long bones, acceleration, fixation, strength, tibia, femur

Θεματική κατηγορία

Παραπομπή

Σύνδεσμος

<Go to ISI>://000236664300007
http://ac.els-cdn.com/S8756328205004333/1-s2.0-S8756328205004333-main.pdf?_tid=29496c95fca7d316661fa871ff5d9ba2&acdnat=1339758321_246b38e1a98821fef2c941373fc4aa42

Γλώσσα

en

Εκδίδον τμήμα/τομέας

Όνομα επιβλέποντος

Εξεταστική επιτροπή

Γενική Περιγραφή / Σχόλια

Ίδρυμα και Σχολή/Τμήμα του υποβάλλοντος

Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Μηχανικών Επιστήμης Υλικών

Πίνακας περιεχομένων

Χορηγός

Βιβλιογραφική αναφορά

Ονόματα συντελεστών

Αριθμός σελίδων

Λεπτομέρειες μαθήματος

item.page.endorsement

item.page.review

item.page.supplemented

item.page.referenced