Monitoring of the avidin-biotylinated dextran interaction on Au- and Ti/TiO2-electrode surfaces using a charge integrating device

dc.contributor.authorBolis, S. D.en
dc.contributor.authorCharalambous, P. C.en
dc.contributor.authorEfstathiou, C. E.en
dc.contributor.authorMantzila, A. G.en
dc.contributor.authorMalamou, C. A.en
dc.contributor.authorProdromidis, M. I.en
dc.date.accessioned2015-11-24T16:42:14Z
dc.date.available2015-11-24T16:42:14Z
dc.identifier.issn0925-4005-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/8524
dc.rightsDefault Licence-
dc.subjectcharge integrationen
dc.subjectcapacitance immunosensorsen
dc.subjectimpedance measurementsen
dc.subjectmonitoring of avidin-biotin interactionsen
dc.subjectimpedance spectroscopyen
dc.subjectimmunosensoren
dc.subjectbiosensorsen
dc.subjectsensorsen
dc.subjectsystemen
dc.titleMonitoring of the avidin-biotylinated dextran interaction on Au- and Ti/TiO2-electrode surfaces using a charge integrating deviceen
heal.abstractIn the present paper we report the use of a homemade electronic device (Multipulser), for monitoring interactions between biomolecules that may change the capacitance of an electrode. Multipulser can be used as a stand-alone, low-cost, yet effective alternative monitoring device instead of other well established commercial instruments. The operation of Multipulser is based on the integration of the electric charge used for the repetitive charging of the electrochemical cell capacitance after the application of a predetermined number of short-duration, low-amplitude voltage pulses (perturbation pulses). Multipulser was used to monitor the binding of biotinylated dextran on two different avidin modified electrode assemblies; one based on a thiol SAMs on gold and another based on Ti/TiO2 semiconductor. Measurements conducted in parallel with a commercial frequency response analyzer gave similar reaction patterns. Pulse polarity dependent behavior was revealed in the case of the Ti/TiO2-electrode assembly when bipolar potential perturbation modes were used with Multipulser. (c) 2005 Elsevier B.V. All rights reserved.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.primaryDOI 10.1016/j.snb.2005.04.006-
heal.identifier.secondary<Go to ISI>://000236009300007-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0925400505004132/1-s2.0-S0925400505004132-main.pdf?_tid=02c5f0de774c68893ce683fdf380ff51&acdnat=1333037087_7b554c962cbdc010fbfce15dfefe3444-
heal.journalNameSensors and Actuators B-Chemicalen
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate2006-
heal.publisherElsevieren
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: