Fabrication and voltammetric study of lanthanum 2,6-dichlorophenolindophenol chemically modified screen printed electrodes. Application for the determination of ascorbic acid

dc.contributor.authorFlorou, A. B.en
dc.contributor.authorProdromidis, M. I.en
dc.contributor.authorTzouwara-Karayanni, S. M.en
dc.contributor.authorKarayannis, M. I.en
dc.date.accessioned2015-11-24T16:58:23Z
dc.date.available2015-11-24T16:58:23Z
dc.identifier.issn0003-2670-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/10683
dc.rightsDefault Licence-
dc.subjectelectrochemical determination of ascorbic aciden
dc.subjectscreen printed electrodesen
dc.subjectbeveragesen
dc.subjectpharmaceuticalsen
dc.subject[dcpi](3)-la-speen
dc.subjectcarbon-paste electrodeen
dc.subjectcobalt phthalocyanineen
dc.subjectelectrocatalytic oxidationen
dc.subjectamperometric determinationen
dc.subjectspectrophotometric methoden
dc.subjectelectrochemical sensoren
dc.subjectproductsen
dc.subjectbehavioren
dc.titleFabrication and voltammetric study of lanthanum 2,6-dichlorophenolindophenol chemically modified screen printed electrodes. Application for the determination of ascorbic aciden
heal.abstractA screen printed carbon electrode (SPCE) impregnated with the electrocatalyst 2,6-dichlorophenolindophenol lanthanum salt ([DCPI](3)La) was constructed. Using cyclic voltammetry the electrochemical behaviour of SPCE, -SPEs and their catalytic effect towards ascorbic acid was investigated. A synthesis protocol ([DCPI](3)La) and some identification studies are given. The fabrication of (SPE) using a mixture of 5% (w/w) [DCPI](3)-La/graphite powder in 1 and 2% (w/v) ethyl cellulose in 2-butoxyethylacetate is also described. Constant potential amperometry in stirred solutions was used for the determination of ascorbic acid in beverages and pharmaceuticals potential of +0.1V versus Ag/AgCl, at pH 7.25 was employed. This technique was also used to assess the reproducibility of the electrode manufacture. Interference of various compounds was also studied. Good correlation with the official titrimetric method was attained. Calibration graphs were linear over the range 0.01-1 mM ascorbic acid and the RSD was 1.8% (n = 9) for 0.6 mM ascorbic acid. Recovery ranged from 91 to 103%. The [DCPI](3)-La-SPE showed very good storage and operational stability. (C) 2000 Elsevier Science B.V. All rights reserved.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.secondary<Go to ISI>://000089924100012-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0003267000010813/1-s2.0-S0003267000010813-main.pdf?_tid=8107990a01754baf3da3c129b2933e68&acdnat=1333037121_c686d2c0c975e5344bf546a393d7d936-
heal.journalNameAnalytica Chimica Actaen
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate2000-
heal.publisherElsevieren
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: