Rapid tracheal infusion of surfactant versus bolus instillation in rabbits: Effects on oxygenation, blood pressure and surfactant distribution

Φόρτωση...
Μικρογραφία εικόνας

Ημερομηνία

Συγγραφείς

Segerer, H.
Scheid, A.
Wagner, M. H.
Lekka, M.
Obladen, M.

Τίτλος Εφημερίδας

Περιοδικό ISSN

Τίτλος τόμου

Εκδότης

Karger

Περίληψη

Τύπος

Είδος δημοσίευσης σε συνέδριο

Είδος περιοδικού

peer reviewed

Είδος εκπαιδευτικού υλικού

Όνομα συνεδρίου

Όνομα περιοδικού

Biology of the Neonate

Όνομα βιβλίου

Σειρά βιβλίου

Έκδοση βιβλίου

Συμπληρωματικός/δευτερεύων τίτλος

Περιγραφή

Surfactant bolus instillation may be associated with a drop in blood pressure, Platelet-activating factor (PAF) has been found in surfactant preparations. The aim of this study was to evaluate rapid tracheal infusion of surfactant during 5 min as an alternative to bolus instillation and to examine whether a PAF receptor antagonist is able to prevent the decrease in blood pressure. Methods: Surfactant deficiency was induced in 16 adult rabbits by lung lavages with saline. Six animals received a bolus of a porcine surfactant preparation (Curosurf((R)) (CS); 200 mg/kg), labeled with red microspheres to assess pulmonary distribution. In another 5 rabbits, the same amount of labelled CS was instilled by tracheal infusion within 5 min. A third group of 5 animals received 3 mg/kg body weight of the PAF antagonist WEB 2170 before CS bolus instillation. Results: After CS bolus administration, mean PaO2 increased by 44.7 +/- 8.3 kPa (mean +/- SD) within 2 min and remained at this level. Mean arterial blood pressure dropped transiently by 2.3 +/- 2 kPa within 5 min. Pulmonary distribution of surfactant was even. After infusion, mean PaO2 rose by 22.4 +/- 16.3 kPa within 15 min. Blood pressure dropped by 1.8 +/- 1.1 kPa within 15 min. The distribution was extremely uneven. Blood pressure decreases also occurred after pretreatment with PAF receptor antagonist. Conclusion: Rapid tracheal infusion of surfactant results in poorer oxygenation, an inhomogeneous distribution and a similar decrease in blood pressure compared to the bolus instillation method. Blood pressure changes could not be prevented by a PAF receptor-specific antagonist.

Περιγραφή

Λέξεις-κλειδιά

respiratory distress syndrome, surfactant substitution, instillation method, pulmonary distribution, animal model, platelet-activating factor, platelet-activating-factor, respiratory-distress syndrome, exogenous surfactant, lung injury, pulmonary distribution, artificial surfactant, preterm infants, permeability, volume, therapy

Θεματική κατηγορία

Παραπομπή

Σύνδεσμος

<Go to ISI>://A1996UA92500007

Γλώσσα

en

Εκδίδον τμήμα/τομέας

Όνομα επιβλέποντος

Εξεταστική επιτροπή

Γενική Περιγραφή / Σχόλια

Ίδρυμα και Σχολή/Τμήμα του υποβάλλοντος

Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας

Πίνακας περιεχομένων

Χορηγός

Βιβλιογραφική αναφορά

Ονόματα συντελεστών

Αριθμός σελίδων

Λεπτομέρειες μαθήματος

item.page.endorsement

item.page.review

item.page.supplemented

item.page.referenced