Determination of the fungicides vinclozolin and dicloran in soils using ultrasonic extraction coupled with solid-phase microextraction

Φόρτωση...
Μικρογραφία εικόνας

Ημερομηνία

Συγγραφείς

Lambropoulou, D. A.
Albanis, T. A.

Τίτλος Εφημερίδας

Περιοδικό ISSN

Τίτλος τόμου

Εκδότης

Περίληψη

Τύπος

Είδος δημοσίευσης σε συνέδριο

Είδος περιοδικού

peer reviewed

Είδος εκπαιδευτικού υλικού

Όνομα συνεδρίου

Όνομα περιοδικού

Analytica Chimica Acta

Όνομα βιβλίου

Σειρά βιβλίου

Έκδοση βιβλίου

Συμπληρωματικός/δευτερεύων τίτλος

Περιγραφή

Solid-phase microextraction (SPME) coupled to ultrasonic extraction was evaluated for extracting trace amounts of two agrochemical fungicides, vinclozolin and dicloran, in soil samples. Extraction was performed following two experimental approaches prior to the submission of the aqueous extracts to SPME-GC analysis. In the first approach, extraction involved sample homogenization with a water solution containing 5% (v/v) acetone and centrifugation prior to fiber extraction. In the second approach, the extraction of the fungicides from the soil samples was conducted using acetone as organic solvent which was then diluted with water to give a 5% (v/v) content. The pesticides were isolated with fused silica fiber coating with 85 mum polyacryl ate. Parameters that affect both the extraction of the fungicides by the soil samples and the trapping of the analytes by the fiber were investigated and their impact on the SPME-GC-MS was studied. The procedures with respect to repeatability and limits of detection were evaluated by soil spiked with both analytes. Repeatability was between 5.6 and 14.2% and the limits of detection were 2-13 ng g(-1). The efficiency of acetone/SPME was generally better than that for water/SPME procedure showing good linearity (R-2 > 0.99) with coefficient variations below 9%, recoveries higher than 91% and limits of detection between 2 and 3 ng g(-1). Finally, the recoveries obtained with acetone/SPME procedure were compared with the conventional liquid-liquid extraction using real soil samples. The acetone/SPME method was shown to be an inexpensive, fast and simple preparation method for the determination of target analytes at low nanogram per gram levels in soils. (C) 2004 Elsevier B.V. All rights reserved.

Περιγραφή

Λέξεις-κλειδιά

vinclozolin, dicloran, soil analysis, solid phase microextraction, water-acetone extraction, gas chromatography/mass spectrometry, polycyclic aromatic-hydrocarbons, microwave-assisted extraction, subcritical water extraction, pesticide-residue analysis, gas-chromatography, natural-waters, environmental antiandrogens, organophosphorus pesticides, organochlorine pesticides, mass-spectrometry

Θεματική κατηγορία

Παραπομπή

Σύνδεσμος

<Go to ISI>://000221834700015
http://ac.els-cdn.com/S0003267004003484/1-s2.0-S0003267004003484-main.pdf?_tid=0083d8ef793f3aa1970580fdc11b4b6c&acdnat=1333023099_e25f14817d927c210a82e4e2a4574064

Γλώσσα

en

Εκδίδον τμήμα/τομέας

Όνομα επιβλέποντος

Εξεταστική επιτροπή

Γενική Περιγραφή / Σχόλια

Ίδρυμα και Σχολή/Τμήμα του υποβάλλοντος

Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας

Πίνακας περιεχομένων

Χορηγός

Βιβλιογραφική αναφορά

Ονόματα συντελεστών

Αριθμός σελίδων

Λεπτομέρειες μαθήματος

item.page.endorsement

item.page.review

item.page.supplemented

item.page.referenced