heal.abstract | In this paper, a controlling circuit is proposed for the management of charge pump circuits. This is achieved with the use of a pattern generator and a feedback circuit so that the produced high voltage of any given charge pump to be tuned to the desired specifications. The output of the pump generates the required high-voltage pattern independently of its load, the temperature variations and the frequency of the clock, while it is operating towards the minimum required power level. (C) 2000 Elsevier Science B.V. All rights reserved. | en |
heal.access | campus | - |
heal.fullTextAvailability | TRUE | - |
heal.journalName | Integration-the Vlsi Journal | en |
heal.journalType | peer reviewed | - |
heal.language | en | - |
heal.publicationDate | 2000 | - |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Μηχανικών Ηλεκτρονικών Υπολογιστών και Πληροφορικής | el |
heal.type | journalArticle | - |
heal.type.el | Άρθρο Περιοδικού | el |
heal.type.en | Journal article | en |