DESIGN AND TEST OF A PROTOTYPE GAS-SAMPLING ELECTROMAGNETIC CALORIMETER OF HIGH GRANULARITY FOR THE CPLEAR EXPERIMENT
| dc.contributor.author | Adler, R. | en |
| dc.contributor.author | Backenstoss, G. | en |
| dc.contributor.author | Bloch, P. | en |
| dc.contributor.author | Damianoglou, D. | en |
| dc.contributor.author | Dechelette, P. | en |
| dc.contributor.author | Droge, M. | en |
| dc.contributor.author | Felder, C. | en |
| dc.contributor.author | Fetscher, W. | en |
| dc.contributor.author | Fidecaro, M. | en |
| dc.contributor.author | Garreta, D. | en |
| dc.contributor.author | Gerber, H. J. | en |
| dc.contributor.author | Gumplinger, P. | en |
| dc.contributor.author | Johner, H. U. | en |
| dc.contributor.author | Kern, J. | en |
| dc.contributor.author | Kokkas, P. | en |
| dc.contributor.author | Mall, U. | en |
| dc.contributor.author | Nanni, F. | en |
| dc.contributor.author | Pavlopoulos, P. | en |
| dc.contributor.author | Renevey, M. | en |
| dc.contributor.author | Santoni, C. | en |
| dc.contributor.author | Schopper, A. | en |
| dc.contributor.author | Tauscher, L. | en |
| dc.contributor.author | Wendler, H. | en |
| dc.contributor.author | Pagels, B. | en |
| dc.contributor.author | Witzig, C. | en |
| dc.date.accessioned | 2015-11-24T18:30:37Z | |
| dc.date.available | 2015-11-24T18:30:37Z | |
| dc.identifier.issn | 0168-9002 | - |
| dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/16388 | |
| dc.rights | Default Licence | - |
| dc.title | DESIGN AND TEST OF A PROTOTYPE GAS-SAMPLING ELECTROMAGNETIC CALORIMETER OF HIGH GRANULARITY FOR THE CPLEAR EXPERIMENT | en |
| heal.abstract | We have designed and tested a gas-sampling calorimeter of high granularity as a prototype for the electromagnetic calorimeter of the CPLEAR experiment. The prototype calorimeter, consisting of 18 layers of 1.5 mm thin lead converters interleaved with a total of 1152 high-gain tubes and 2304 pick-up strips, was tested in a tagged photon beam with photons in the energy range of 50 to 350 MeV. It well fulfilled the requirements of a good detection efficiency for photons above 50 MeV with a spatial resolution sigma almost-equal-to 5 mm for the photon conversion point and an energy resolution sigma(E)/E almost-equal-to 15% square-root E[GeV]. | en |
| heal.access | campus | - |
| heal.fullTextAvailability | TRUE | - |
| heal.identifier.primary | 10.1016/0168-9002(92)90055-9 | - |
| heal.identifier.secondary | <Go to ISI>://WOS:A1992JR50700007 | - |
| heal.identifier.secondary | http://ac.els-cdn.com/0168900292900548/1-s2.0-0168900292900548-main.pdf?_tid=eda81d3e5555186dd9f3647cf46de1a3&acdnat=1334228365_aa1fcc5f7ccfa5e58afc4bf14c5a6c91 | - |
| heal.journalName | Nuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipment | en |
| heal.journalType | peer reviewed | - |
| heal.publicationDate | 1992 | - |
| heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών και Τεχνολογιών. Τμήμα Βιολογικών Εφαρμογών και Τεχνολογιών | el |
| heal.type | journalArticle | - |
| heal.type.el | Άρθρο Περιοδικού | el |
| heal.type.en | Journal article | en |
Αρχεία
Φάκελος/Πακέτο αδειών
1 - 1 of 1
Φόρτωση...
- Ονομα:
- license.txt
- Μέγεθος:
- 1.74 KB
- Μορφότυπο:
- Item-specific license agreed upon to submission
- Περιγραφή: