Application of chemometric assisted dispersive liquid-liquid microextraction to the determination of personal care products in natural waters
dc.contributor.author | Panagiotou, A. N. | en |
dc.contributor.author | Sakkas, V. A. | en |
dc.contributor.author | Albanis, T. A. | en |
dc.date.accessioned | 2015-11-24T16:52:30Z | |
dc.date.available | 2015-11-24T16:52:30Z | |
dc.identifier.issn | 0003-2670 | - |
dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/9895 | |
dc.rights | Default Licence | - |
dc.subject | experimental design | en |
dc.subject | response surface methodology | en |
dc.subject | phthalic acid esters | en |
dc.subject | polycyclic musks | en |
dc.subject | electron-capture detection | en |
dc.subject | solid-phase microextraction | en |
dc.subject | chromatography-mass spectrometry | en |
dc.subject | single-drop microextraction | en |
dc.subject | flame photometric detection | en |
dc.subject | polycyclic musk fragrances | en |
dc.subject | gas-chromatography | en |
dc.subject | waste-water | en |
dc.subject | phthalate-esters | en |
dc.subject | capillary-electrophoresis | en |
dc.title | Application of chemometric assisted dispersive liquid-liquid microextraction to the determination of personal care products in natural waters | en |
heal.abstract | A rapid and simple method for the determination of two phthalates and five polycyclic musks in water samples using dispersive liquid-liquid microextraction (DLLME) mated to chemometrics and coupled to GC-MS was developed. Volume of extraction (CCl(4)) and disperser solvent (MeOH), pH, ionic strength, extraction time, centrifugation time as well as centrifugation speed were optimized in a 2(7-4) Plackett-Burman design. The obtained significant factors were optimized by using a central composite design (CCD) and the quadratic model between the dependent and the independent variables was built. The optimum experimental conditions of the proposed method were: 250 mu L, carbon tetrachloride, 0.62 ml, methanol, 7.5 min centrifugation time, natural pH containing 0% (w/v) NaCl, while keeping centrifugation speed fixed at 4000 rpm. The calculated calibration curves gave high-level linearity for all target analytes with correlation coefficients ranging between 0.9970 and 0.9992. The repeatability and reproducibility of the proposed method, expressed as relative standard deviation, varied between 2.6% to 9.7% and 5.7% to 12.2%, respectively. The obtained LOD values were in the range of 8-63 ng L(-1). (C) 2009 Elsevier B.V. All rights reserved. | en |
heal.access | campus | - |
heal.fullTextAvailability | TRUE | - |
heal.identifier.primary | DOI 10.1016/j.aca.2009.07.028 | - |
heal.identifier.secondary | <Go to ISI>://000269652800001 | - |
heal.identifier.secondary | http://ac.els-cdn.com/S0003267009009337/1-s2.0-S0003267009009337-main.pdf?_tid=e4db451b959a6a45cf265c57e9b95789&acdnat=1333023260_7cd1d95c9fe9d024b525e12ab9c39b92 | - |
heal.journalName | Analytica Chimica Acta | en |
heal.journalType | peer reviewed | - |
heal.language | en | - |
heal.publicationDate | 2009 | - |
heal.publisher | Elsevier | en |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας | el |
heal.type | journalArticle | - |
heal.type.el | Άρθρο Περιοδικού | el |
heal.type.en | Journal article | en |
Αρχεία
Φάκελος/Πακέτο αδειών
1 - 1 of 1
Φόρτωση...
- Ονομα:
- license.txt
- Μέγεθος:
- 1.74 KB
- Μορφότυπο:
- Item-specific license agreed upon to submission
- Περιγραφή: