Single-drop liquid-phase microextraction for the determination of hypericin, pseudohypericin and hyperforin in biological fluids by high performance liquid chromatography

Φόρτωση...
Μικρογραφία εικόνας

Ημερομηνία

Συγγραφείς

Gioti, E. M.
Skalkos, D. C.
Fiamegos, Y. C.
Stalikas, C. D.

Τίτλος Εφημερίδας

Περιοδικό ISSN

Τίτλος τόμου

Εκδότης

Elsevier

Περίληψη

Τύπος

Είδος δημοσίευσης σε συνέδριο

Είδος περιοδικού

peer reviewed

Είδος εκπαιδευτικού υλικού

Όνομα συνεδρίου

Όνομα περιοδικού

Journal of Chromatography A

Όνομα βιβλίου

Σειρά βιβλίου

Έκδοση βιβλίου

Συμπληρωματικός/δευτερεύων τίτλος

Περιγραφή

The analysis of hypericin, pseudohypericin (collectively called in this study hypericins) and hyperforin in biological fluids is reported using single-drop liquid-phase microextraction in conjunction with HPLC-UV-fluorescence detection. A new option for analysis of the active principle constituents in biological samples is proposed, reducing the steps required prior to analysis. There are several parameters which determine the mass transfer such as the extraction solvent, drop and sample volumes, extraction time and temperature, pH and ionic strength, stirring rate and depth of needle tip in the bulk solution. These parameters were chosen to optimize the performance in the current study. The method was validated with respect to precision, accuracy and specificity. The intra-day precision values were below 2.3% for the high concentration level of control samples and 6.2% for the low level. The respective inter-day precision values were calculated to be below 4.4 and 7.1%, respectively, for the two concentration levels. Accuracy of the method, calculated as relative error, ranged from -2.6 to 7.0%. It was demonstrated that as long as the extraction procedure is consistently applied, quantitative analysis is performed accurately and reproducibly in human urine and plasma samples. Limits of quantitation (LOQs) in urine were calculated to be 3, 6 and 12 ng/ml for pseudohypericin, hypericin and hyperforin, respectively. Slightly higher limits were measured in plasma, i.e. 5, 12 and 20 ng/ml, for the respective analytes. (c) 2005 Elsevier B.V. All rights reserved.

Περιγραφή

Λέξεις-κλειδιά

pseudohypericin, hypericin, hyperforin, analysis, biological fluids, single-drop liquid-phase microextraction, st-johns-wort, antidepressant activity, mass-spectrometry, perforatum l, solvent microextraction, gas-chromatography, water samples, human plasma, extraction, cytotoxicity

Θεματική κατηγορία

Παραπομπή

Σύνδεσμος

<Go to ISI>://000232957900001
http://ac.els-cdn.com/S0021967305015116/1-s2.0-S0021967305015116-main.pdf?_tid=81648b9237fa4014f3b783820a1908f0&acdnat=1333040801_dd07843f4148a977dc07b44606b6be21

Γλώσσα

en

Εκδίδον τμήμα/τομέας

Όνομα επιβλέποντος

Εξεταστική επιτροπή

Γενική Περιγραφή / Σχόλια

Ίδρυμα και Σχολή/Τμήμα του υποβάλλοντος

Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας

Πίνακας περιεχομένων

Χορηγός

Βιβλιογραφική αναφορά

Ονόματα συντελεστών

Αριθμός σελίδων

Λεπτομέρειες μαθήματος

item.page.endorsement

item.page.review

item.page.supplemented

item.page.referenced