Low detection limit spectrophotometry

dc.contributor.authorDemertzis, M. A.en
dc.date.accessioned2015-11-24T16:41:14Z
dc.date.available2015-11-24T16:41:14Z
dc.identifier.issn0003-2670-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/8386
dc.rightsDefault Licence-
dc.subjectlimit spectrophotometryen
dc.subjectbeer's lawen
dc.subject1,10-phenanthrolineen
dc.subjectflow-injection systemen
dc.subjectironen
dc.subject1,10-phenanthrolineen
dc.subjectspeciationen
dc.subjectiron(iii)en
dc.subjectcopperen
dc.subjectcellsen
dc.titleLow detection limit spectrophotometryen
heal.abstractAn efficient, more sensitive and accurate spectrophotometric process is possible and can be used to obtain qualitative or quantitative results for analytes at limiting concentrations lower than usual. Transmission measurements (incident light power, P-0, or transmitted, P) are performed with a fluorescence spectrometer. One cell only is used to measure standards or unknown solutions, placed between the standard holder cuvette and the emission monochromator of the instrument. The source of the radiant power (P-0) is not the xenon lamp but the fluorescence or scattered radiation from the holder cuvette filled with an appropriate solution. The analyte concentration is found from a calibration graph, based upon Beer's law or the approximate formula P-0 - P = 2.303P(0)epsilonbc, which is valid for dilute solutions. Determination of iron in a reference material, using 1,10-phenanthroline as the chromogenic reagent, was chosen as an example to demonstrate the suitability of the proposed method and clarify several important statistical questions. Also discussed is why and to what extent molecular fluorescence methods are more sensitive than molecular absorption methods. (C) 2003 Elsevier B.V. All rights reserved.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.primaryDoi 10.1016/S0003-2670(03)00512-9-
heal.identifier.secondary<Go to ISI>://000189102800011-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0003267003005129/1-s2.0-S0003267003005129-main.pdf?_tid=d4a64c1c894522509484281f86a3fd8b&acdnat=1333028436_37c7dcd5a8329de16ef33672d4d4f268-
heal.journalNameAnalytica Chimica Actaen
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate2004-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: