Microbeam radiation therapy: tissue dose penetration and BANG-gel dosimetry of thick-beams' array interlacing

Loading...
Thumbnail Image

Date

Authors

Dilmanian, F. A.
Romanelli, P.
Zhong, Z.
Wang, R.
Wagshul, M. E.
Kalef-Ezra, J.
Maryanski, M. J.
Rosen, E. M.
Anschel, D. J.

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Type of the conference item

Journal type

peer-reviewed

Educational material type

Conference Name

Journal name

Eur J Radiol

Book name

Book series

Book edition

Alternative title / Subtitle

Description

The tissue-sparing effect of parallel, thin (narrower than 100 microm) synchrotron-generated X-ray planar beams (microbeams) in healthy tissues including the central nervous system (CNS) is known since early 1990 s. This, together with a remarkable preferential tumoricidal effect of such beam arrays observed at high doses, has been the basis for labeling the method microbeam radiation therapy (MRT). Recent studies showed that beams as thick as 0.68 mm ("thick microbeams") retain part of their sparing effect in the rat's CNS, and that two such orthogonal microbeams arrays can be interlaced to produce an unsegmented field at the target, thus producing focal targeting. We measured the half-value layer (HVL) of our 120-keV median-energy beam in water phantoms, and we irradiated stereotactically bis acrylamide nitrogen gelatin (BANG)-gel-filled phantoms, including one containing a human skull, with interlaced microbeams and imaged them with MRI. A 43-mm water HVL resulted, together with an adequately large peak-to-valley ratio of the microbeams' three-dimensional dose distribution in the vicinity of the 20 mm x 20 mm x 20 mm target deep into the skull. Furthermore, the 80-20% dose fall off was a fraction of a millimeter as predicted by Monte Carlo simulations. We conclude that clinical MRT will benefit from the use of higher beam energies than those used here, although the current energy could serve certain neurosurgical applications. Furthermore, thick microbeams particularly when interlaced present some advantages over thin microbeams in that they allow the use of higher beam energies and they could conceivably be implemented with high power orthovoltage X-ray tubes.

Description

Keywords

Algorithms, Brain/*physiology/*radiation effects, Computer Simulation, Gels/radiation effects, Humans, *Models, Biological, Monte Carlo Method, Radiometry/*methods, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted/*methods, Radiotherapy, High-Energy/*methods, Scattering, Radiation, *Synchrotrons

Subject classification

Citation

Link

http://www.ncbi.nlm.nih.gov/pubmed/18606516
http://ac.els-cdn.com/S0720048X08002970/1-s2.0-S0720048X08002970-main.pdf?_tid=077c6d69a239672178f2a17d5f8865e4&acdnat=1333088221_653fcaade346cfa6e7a32b8b8ea54e88

Language

en

Publishing department/division

Advisor name

Examining committee

General Description / Additional Comments

Institution and School/Department of submitter

Πανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών Υγείας. Τμήμα Ιατρικής

Table of contents

Sponsor

Bibliographic citation

Name(s) of contributor(s)

Number of Pages

Course details

Endorsement

Review

Supplemented By

Referenced By