Microbeam radiation therapy: tissue dose penetration and BANG-gel dosimetry of thick-beams' array interlacing
Φόρτωση...
Ημερομηνία
Τίτλος Εφημερίδας
Περιοδικό ISSN
Τίτλος τόμου
Εκδότης
Περίληψη
Τύπος
Είδος δημοσίευσης σε συνέδριο
Είδος περιοδικού
peer-reviewed
Είδος εκπαιδευτικού υλικού
Όνομα συνεδρίου
Όνομα περιοδικού
Eur J Radiol
Όνομα βιβλίου
Σειρά βιβλίου
Έκδοση βιβλίου
Συμπληρωματικός/δευτερεύων τίτλος
Περιγραφή
The tissue-sparing effect of parallel, thin (narrower than 100 microm) synchrotron-generated X-ray planar beams (microbeams) in healthy tissues including the central nervous system (CNS) is known since early 1990 s. This, together with a remarkable preferential tumoricidal effect of such beam arrays observed at high doses, has been the basis for labeling the method microbeam radiation therapy (MRT). Recent studies showed that beams as thick as 0.68 mm ("thick microbeams") retain part of their sparing effect in the rat's CNS, and that two such orthogonal microbeams arrays can be interlaced to produce an unsegmented field at the target, thus producing focal targeting. We measured the half-value layer (HVL) of our 120-keV median-energy beam in water phantoms, and we irradiated stereotactically bis acrylamide nitrogen gelatin (BANG)-gel-filled phantoms, including one containing a human skull, with interlaced microbeams and imaged them with MRI. A 43-mm water HVL resulted, together with an adequately large peak-to-valley ratio of the microbeams' three-dimensional dose distribution in the vicinity of the 20 mm x 20 mm x 20 mm target deep into the skull. Furthermore, the 80-20% dose fall off was a fraction of a millimeter as predicted by Monte Carlo simulations. We conclude that clinical MRT will benefit from the use of higher beam energies than those used here, although the current energy could serve certain neurosurgical applications. Furthermore, thick microbeams particularly when interlaced present some advantages over thin microbeams in that they allow the use of higher beam energies and they could conceivably be implemented with high power orthovoltage X-ray tubes.
Περιγραφή
Λέξεις-κλειδιά
Algorithms, Brain/*physiology/*radiation effects, Computer Simulation, Gels/radiation effects, Humans, *Models, Biological, Monte Carlo Method, Radiometry/*methods, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted/*methods, Radiotherapy, High-Energy/*methods, Scattering, Radiation, *Synchrotrons
Θεματική κατηγορία
Παραπομπή
Σύνδεσμος
http://www.ncbi.nlm.nih.gov/pubmed/18606516
http://ac.els-cdn.com/S0720048X08002970/1-s2.0-S0720048X08002970-main.pdf?_tid=077c6d69a239672178f2a17d5f8865e4&acdnat=1333088221_653fcaade346cfa6e7a32b8b8ea54e88
http://ac.els-cdn.com/S0720048X08002970/1-s2.0-S0720048X08002970-main.pdf?_tid=077c6d69a239672178f2a17d5f8865e4&acdnat=1333088221_653fcaade346cfa6e7a32b8b8ea54e88
Γλώσσα
en
Εκδίδον τμήμα/τομέας
Όνομα επιβλέποντος
Εξεταστική επιτροπή
Γενική Περιγραφή / Σχόλια
Ίδρυμα και Σχολή/Τμήμα του υποβάλλοντος
Πανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών Υγείας. Τμήμα Ιατρικής
