L-line x-ray fluorescence of cortical bone lead compared with the CaNa2EDTA test in lead-toxic children: public health implications
dc.contributor.author | Rosen, J. F. | en |
dc.contributor.author | Markowitz, M. E. | en |
dc.contributor.author | Bijur, P. E. | en |
dc.contributor.author | Jenks, S. T. | en |
dc.contributor.author | Wielopolski, L. | en |
dc.contributor.author | Kalef-Ezra, J. A. | en |
dc.contributor.author | Slatkin, D. N. | en |
dc.date.accessioned | 2015-11-24T19:06:39Z | |
dc.date.available | 2015-11-24T19:06:39Z | |
dc.identifier.issn | 0027-8424 | - |
dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/20364 | |
dc.rights | Default Licence | - |
dc.subject | Bone and Bones/*analysis | en |
dc.subject | Child | en |
dc.subject | Child, Preschool | en |
dc.subject | Edetic Acid | en |
dc.subject | Humans | en |
dc.subject | Infant | en |
dc.subject | Lead/*analysis/blood/urine | en |
dc.subject | Lead Poisoning/*diagnosis | en |
dc.subject | Predictive Value of Tests | en |
dc.subject | Spectrometry, X-Ray Emission | en |
dc.title | L-line x-ray fluorescence of cortical bone lead compared with the CaNa2EDTA test in lead-toxic children: public health implications | en |
heal.abstract | Mild to moderate lead toxicity (blood lead, 25-55 micrograms/dl) is a preventable pediatric illness affecting several million preschool children ("lead-toxic children") in the United States. In-hospital lead-chelation treatment is predicated upon a positive CaNa2EDTA test, which is difficult to perform and impractical in large populations. After the development of an L-line x-ray fluorescence technique (LXRF) that measures cortical bone lead content safely, rapidly, and noninvasively, this study was initiated in lead-toxic children to compare LXRF with the CaNa2EDTA test. Moreover, LXRF provided the opportunity to quantify bone lead content. From blood lead and LXRF alone, 90% of lead-toxic children were correctly classified as being CaNa2EDTA-positive or -negative. In 76% of 59 lead-toxic children, bone lead values measured by LXRF were equal to or greater than those measured in normal and industrially exposed adults. These results indicate that LXRF may be capable of replacing the CaNa2EDTA test. When considered with the known neurotoxic effects on children of "low levels" of exposure to lead, these results also suggest that either an excessively narrow margin of safety or insufficient safety is provided by present U.S. guidelines, which classify an elevated blood lead concentration as 25 micrograms/dl or greater. | en |
heal.access | campus | - |
heal.fullTextAvailability | TRUE | - |
heal.identifier.secondary | http://www.ncbi.nlm.nih.gov/pubmed/2492111 | - |
heal.identifier.secondary | http://www.pnas.org/content/86/2/685.full.pdf | - |
heal.journalName | Proc Natl Acad Sci U S A | en |
heal.journalType | peer-reviewed | - |
heal.language | en | - |
heal.publicationDate | 1989 | - |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών Υγείας. Τμήμα Ιατρικής | el |
heal.type | journalArticle | - |
heal.type.el | Άρθρο Περιοδικού | el |
heal.type.en | Journal article | en |
Αρχεία
Πρωτότυπος φάκελος/πακέτο
1 - 1 of 1
Φόρτωση...
- Ονομα:
- Rosen-1989-L-line x-ray fluores.pdf
- Μέγεθος:
- 1.02 MB
- Μορφότυπο:
- Adobe Portable Document Format
Φάκελος/Πακέτο αδειών
1 - 1 of 1
Φόρτωση...
- Ονομα:
- license.txt
- Μέγεθος:
- 1.74 KB
- Μορφότυπο:
- Item-specific license agreed upon to submission
- Περιγραφή: