Phase-transfer catalytic determination of phenols as methylated derivatives by gas chromatography with flame ionization and mass-selective detection

dc.contributor.authorFiamegos, Y. C.en
dc.contributor.authorNanos, C. G.en
dc.contributor.authorPilidis, G. A.en
dc.contributor.authorStalikas, C. D.en
dc.date.accessioned2015-11-24T16:44:26Z
dc.date.available2015-11-24T16:44:26Z
dc.identifier.issn0021-9673-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/8800
dc.rightsDefault Licence-
dc.subjectphase-transfer catalysisen
dc.subjectphenolsen
dc.subjectchlorophenolsen
dc.subjectnitrophenolsen
dc.subjectspectrophotometric determinationen
dc.subjectquaternary ammoniumen
dc.subjecttriphase catalysisen
dc.subjectphosphonium saltsen
dc.subjectspectrometryen
dc.subjectextractionen
dc.subjectderivatizationen
dc.subjectethersen
dc.subjecturineen
dc.subjectwateren
dc.titlePhase-transfer catalytic determination of phenols as methylated derivatives by gas chromatography with flame ionization and mass-selective detectionen
heal.abstractA convenient method for the GC determination of phenols as methylated derivatives is proposed, taking advantage of the beneficial features of phase-transfer catalysis (PTC). The optimal experimental conditions of pH, temperature, organic solvent, time of extraction-derivatization and amounts of the participating reactants and catalysts, were properly established. Several catalysts in soluble or polymer-bound form were tested. Most of them demonstrated appreciably high-performance characteristics but the polymer-bound catalyst is most favourable due to its facile separation from the rest of the reaction system after the extraction-derivatization. Interferences with the extraction and derivatization yield were not noticed. The chromatographic separation of 11 methylated derivatives of phenols was complete within 23 min. The detection limits of the method, which range from 0.005 to 0.120 mug, are inadequate for drinking water analysis. However, the method was successfully applied to the analysis of fortified composite lake water samples using GC-flame ionization detection and GC-MS in the single ion monitoring mode with the most abundant characteristic ions. Spiked recoveries of phenolics were in the range 94-102%, on the basis of distilled water calibration graph, signifying that PTC determination of phenols is not affected by the composition of such matrices. (C) 2002 Elsevier Science B.V. All rights reserved.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.primary10.1016/S0021-9673(02)01728-4-
heal.identifier.secondary<Go to ISI>://000180309500019-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0021967302017284/1-s2.0-S0021967302017284-main.pdf?_tid=4ffd1be6c94cc833f710e17d3ccfd299&acdnat=1333040737_ce0f62b04ed958f37fb874e1bd3cab1d-
heal.journalNameJournal of Chromatography Aen
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate2003-
heal.publisherElsevieren
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: