Sensitive Atmospheric-Pressure Detection of Nitroaromatic Compounds and Nox (X=1,2) Molecules in an Ionization-Chamber Using Resonance-Enhanced Multiphoton Ionization

dc.contributor.authorMarshall, A.en
dc.contributor.authorClark, A.en
dc.contributor.authorDeas, R. M.en
dc.contributor.authorKosmidis, C.en
dc.contributor.authorLedingham, K. W. D.en
dc.contributor.authorPeng, W.en
dc.contributor.authorSinghal, R. P.en
dc.date.accessioned2015-11-24T18:35:38Z
dc.date.available2015-11-24T18:35:38Z
dc.identifier.issn0003-2654-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/17120
dc.rightsDefault Licence-
dc.subjectresonance-enhanced multiphoton ionizationen
dc.subjectnitroaromatic vaporen
dc.subjectionization chamber detectionen
dc.subjectsensitivityen
dc.subjectnox moleculeen
dc.subjection mobility spectrometryen
dc.subjectlaser-produced ionsen
dc.subjectmultiphoton ionizationen
dc.subjectmass-spectrometryen
dc.subjectfragmentationen
dc.subjectdissociationen
dc.subjectvaporsen
dc.titleSensitive Atmospheric-Pressure Detection of Nitroaromatic Compounds and Nox (X=1,2) Molecules in an Ionization-Chamber Using Resonance-Enhanced Multiphoton Ionizationen
heal.abstractNitrobenzene and o-nitrotoluene were detected in trace concentrations in gas mixtures at atmospheric pressure in a simple unity-gain ionization chamber. The detection procedure relies on tunable ultraviolet laser radiation that identifies the characteristic wavelength dependence of the NO+ ion fragment. Sensitivity levels are 0.25 +/- 0.05 ppm for nitrobenzene and 0.75 +/- 0.1 ppm for o-nitrotoluene, with the current limitations being background ionization, laser power and small sampling volume. Additionally, nominally 1 ppm NO and NO2 gas samples were analysed and the saturation fluence (via a resonant two-photon process at 226.3 nm) for NO+ production from NO gas was determined. Sensitivity levels of 120 and 50 ppb were estimated from the data on NO2 and NO, respectively. It is shown that an increase in sensitivity of an order of magnitude is possible in all instances if the experimental parameters are optimized.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.secondary<Go to ISI>://A1994PE57400012-
heal.identifier.secondaryhttp://pubs.rsc.org/en/Content/ArticleLanding/1994/AN/an9941901719-
heal.journalNameAnalysten
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate1994-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών και Τεχνολογιών. Τμήμα Βιολογικών Εφαρμογών και Τεχνολογιώνel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: