On-site monitoring of fish spoilage using vanadium pentoxide xerogel modified interdigitated gold electrodes

dc.contributor.authorHelali, S.en
dc.contributor.authorAbdelghani, A.en
dc.contributor.authorJaffrezic-Renault, N.en
dc.contributor.authorTrikalitis, P. N.en
dc.contributor.authorEfstathiou, C. E.en
dc.contributor.authorProdromidis, M. I.en
dc.date.accessioned2015-11-24T16:43:25Z
dc.date.available2015-11-24T16:43:25Z
dc.identifier.issn0013-4686-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/8696
dc.rightsDefault Licence-
dc.subjectvanadium pentoxide xerogelen
dc.subjectinterdigitated gold electrodesen
dc.subjectammonia chemical sensoren
dc.subjecton-siteen
dc.subjectreal-time monitoring of fish spoilageen
dc.subjecttvb-nen
dc.subjectfreshnessen
dc.subjectfilmen
dc.titleOn-site monitoring of fish spoilage using vanadium pentoxide xerogel modified interdigitated gold electrodesen
heal.abstractThe development of a vanadium pentoxide xerogel (VXG)-based sensor for the detection of volatile inorganic (ammonia) and organic (dimethylamine, etc.) amines is described. The xerogel film was deposited on interdigitated gold electrodes by dip-coating using an aqueous solution of VXG. The morphology of the sensing layer, its interaction with ammonia, which was used as a model analyte throughout this work, as well as the regeneration of the surface of the sensor electrodes with vapors of HCl were examined with scanning electron microscopy and FTIR spectroscopy. Signal changes, due to changes of the RC-product of the electrochemical cell (Au-VXG-Au), as a result of its interactions with ammonia vapors, were probed with a portable, homemade charge meter, the Multipulser. Exposing the sensor electrodes to various concentrations of ammonia vapors resulted in proportional changes in the signal output. Finally, the proposed sensors were successfully used for on-site, real-time monitoring of fish spoilage in ambient conditions. (C) 2009 Elsevier Ltd. All rights reserved.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.primaryDOI 10.1016/j.electacta.2009.01.027-
heal.identifier.secondary<Go to ISI>://000277872500007-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0013468609001042/1-s2.0-S0013468609001042-main.pdf?_tid=6f8a4de33a487b80d0df904aa1e7f7ef&acdnat=1333037152_b33d1c741947a648b2bbc8cdaec9b271-
heal.journalNameElectrochimica Actaen
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate2010-
heal.publisherElsevieren
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: