Luminol chemiluminescense reaction: a new method for monitoring nitric oxide in vivo

dc.contributor.authorYao, D. C.en
dc.contributor.authorVlessidis, A. G.en
dc.contributor.authorEvmiridis, N. P.en
dc.contributor.authorEvangelou, A.en
dc.contributor.authorKarkabounas, S.en
dc.contributor.authorTsampalas, S.en
dc.date.accessioned2015-11-24T16:41:16Z
dc.date.available2015-11-24T16:41:16Z
dc.identifier.issn0003-2670-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/8394
dc.rightsDefault Licence-
dc.subjectnitric oxideen
dc.subjectin vivo monitoringen
dc.subjectmicrodialysis samplingen
dc.subjectchemiluminescenceen
dc.subjectviagraen
dc.subjectflow-injectionen
dc.subjectrelaxing factoren
dc.subjectl-arginineen
dc.subjectnoen
dc.subjectsuperoxideen
dc.subjectmechanismen
dc.subjectsynthaseen
dc.subjectsystemen
dc.subjectsensoren
dc.subjectassayen
dc.titleLuminol chemiluminescense reaction: a new method for monitoring nitric oxide in vivoen
heal.abstractA new method employing a combination of microdialysis sampling and chemiluminescence (CL) detection was developed to monitor nitric oxide (NO) in vivo. A special probe was designed with an interference-free membrane to achieve very high selectivity for NO. High sensitivity was achieved by optimizing the working system and improving the NO sampling time. This system was used in vivo to monitor blood and brain tissue in rats and rabbits. The system is sensitive enough to detect variations of NO formation under different physiological states. The linear valid range of NO determination is 5 nM to 1 muM, with a 3sigma detection limit of I nM; real NO concentrations in test animals used in this work were found to be in the range of 1-5 nM or even less. Finally, the effects of body temperature, NO donors, Viagra, NO activators, NO cofactors and NO interference (such as O-2) were investigated carefully in different physiological situations. (C) 2002 Elsevier Science B.V. All rights reserved.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.primaryDoi 10.1016/S0003-2670(02)00070-3-
heal.identifier.secondary<Go to ISI>://000175752500003-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0003267002000703/1-s2.0-S0003267002000703-main.pdf?_tid=98fcc02a-356a-11e3-a246-00000aacb35e&acdnat=1381821950_6a27f4e8a15c85565b6f13db7c65265d-
heal.journalNameAnalytica Chimica Actaen
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate2002-
heal.publisherElsevier Massonen
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: