Flame atomic absorption determination of lead through on-line preconcentration by surfactant mediated glass wool retention
dc.contributor.author | Katsaounos, C. Z. | en |
dc.contributor.author | Paleologos, E. K. | en |
dc.contributor.author | Karayannis, M. I. | en |
dc.date.accessioned | 2015-11-24T16:38:03Z | |
dc.date.available | 2015-11-24T16:38:03Z | |
dc.identifier.issn | 0306-7319 | - |
dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/7992 | |
dc.rights | Default Licence | - |
dc.subject | controlled pore glass-glass-wool-packed minicolumn | en |
dc.subject | high-surface-area substrate | en |
dc.subject | determination of lead | en |
dc.subject | on-line surfactant mediated preconcentration | en |
dc.subject | atomic absorption spectrometry | en |
dc.subject | anionic surfactants | en |
dc.subject | separation approach | en |
dc.subject | extraction | en |
dc.subject | spectrometry | en |
dc.subject | chromium | en |
dc.subject | samples | en |
dc.title | Flame atomic absorption determination of lead through on-line preconcentration by surfactant mediated glass wool retention | en |
heal.abstract | This work reports on the fabrication of a mini column packed with controlled pore glass and glass wool, and its application for the on-line preconcentration of lead with the aid of an anionic surfactant ( sodium dodecyl sulphate, SDS) and AAS detection. Lead reacts with SDS in a highionic-strength environment, and the product is retained and preconcentrated on a high-surface area substrate like glass wool. The intervention of controlled pore glass increases the active surface of glasswool and prevents its accumulation into a sticky mass after wetting. Washing the mini column with a methanolic solution of HNO3, causes the retained micellar face to be eluted, and consequently the lead content can be determined with AAS. A preconcentration factor of 50 along with a signal enhancement due to the combined presence of SDS and methanol yields a detection limit of 1.5 mu g L-1. The correlation coefficient of the calibration curve is 0.999, and the linear range 5-500 mu g L-1. The method was used for the determination of lead in water and wastewater with good results. | en |
heal.access | campus | - |
heal.fullTextAvailability | TRUE | - |
heal.identifier.primary | Doi 10.1080/03067310500247561 | - |
heal.identifier.secondary | <Go to ISI>://000234969700006 | - |
heal.identifier.secondary | http://www.tandfonline.com/doi/pdf/10.1080/03067310500247561 | - |
heal.journalName | International Journal of Environmental Analytical Chemistry | en |
heal.journalType | peer reviewed | - |
heal.language | en | - |
heal.publicationDate | 2006 | - |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας | el |
heal.type | journalArticle | - |
heal.type.el | Άρθρο Περιοδικού | el |
heal.type.en | Journal article | en |
Αρχεία
Φάκελος/Πακέτο αδειών
1 - 1 of 1
Φόρτωση...
- Ονομα:
- license.txt
- Μέγεθος:
- 1.74 KB
- Μορφότυπο:
- Item-specific license agreed upon to submission
- Περιγραφή: