Development of an interference-free chemiluminescence method for monitoring acetylcholine and choline based on immobilized enzymes

dc.contributor.authorYao, D.en
dc.contributor.authorVlessidis, A. G.en
dc.contributor.authorEvmiridis, N. P.en
dc.date.accessioned2015-11-24T16:56:03Z
dc.date.available2015-11-24T16:56:03Z
dc.identifier.issn0003-2670-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/10385
dc.rightsDefault Licence-
dc.subjectacetylcholineen
dc.subjectcholineen
dc.subjectchemiluminescenceen
dc.subjectluminolen
dc.subjectenzyme immobilizationen
dc.subjectmembraneen
dc.subjecthydrogen-peroxideen
dc.subjectflow-injectionen
dc.subjectliquid-chromatographyen
dc.subjectelectrodeen
dc.subjectsensorsen
dc.subjectglucoseen
dc.subjectoxidaseen
dc.subjecteliminationen
dc.subjectbiosensorsen
dc.titleDevelopment of an interference-free chemiluminescence method for monitoring acetylcholine and choline based on immobilized enzymesen
heal.abstractAnew detection method for measurement of acetylcholine (Ach) and choline (Ch) was developed, the H2O2 that is generated in enzymatic conversion action from Ach or Ch was detected through the luminol-hexacyanoferrate based chemiluminescence (CL) reaction. A new enzyme immobilization method was developed and an interference-free membrane was prepared to achieve a higher sensor response with good selectivity and stability for detection of Ach and Ch. A novel sample preparation method was developed to extract Ach and Ch from nerve tissue efficiently, and the Ach and Ch were detected by Ach and Ch sensors with very high sensitivity and reasonable precision. The Ch sensor has a detection limit (signal/noise = 3) of 0.03 pmol (0.25 nM x 120 mul) with a linear range of 4 x 10(-8) to 1 x 10(-4) M. The Ach sensor has a detection limit of 1.2 pmol (10 nM x 120 mul) with linear range of 6 x 10(-8) to 1 x 10(-4) M. The sensitivity was improved more than 10-fold compared to the previous CL method. (C) 2002 Elsevier Science B.V. All rights reserved.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.primaryDoi 10.1016/S0003-2670(02)00336-7-
heal.identifier.secondary<Go to ISI>://000176637400007-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0003267002003367/1-s2.0-S0003267002003367-main.pdf?_tid=925857ac-356a-11e3-8d76-00000aacb360&acdnat=1381821939_ed85e9ac473407d5abb9b868abf22e1e-
heal.journalNameAnalytica Chimica Actaen
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate2002-
heal.publisherElsevier Massonen
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: