Simultaneous spectra-kinetic determination of peracetic acid and hydrogen peroxide in a brewery cleaning-in-place disinfection process
dc.contributor.author | Pettas, I. A. | en |
dc.contributor.author | Karayannis, M. I. | en |
dc.date.accessioned | 2015-11-24T16:47:23Z | |
dc.date.available | 2015-11-24T16:47:23Z | |
dc.identifier.issn | 0003-2670 | - |
dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/9173 | |
dc.rights | Default Licence | - |
dc.subject | peracetic acid | en |
dc.subject | peroxides | en |
dc.subject | disinfectant determination | en |
dc.subject | chemometric spectra-kinetic analysis | en |
dc.subject | stopped-flow techniques | en |
dc.subject | decomposition | en |
dc.subject | nickel | en |
dc.subject | cobalt | en |
dc.subject | iron | en |
dc.title | Simultaneous spectra-kinetic determination of peracetic acid and hydrogen peroxide in a brewery cleaning-in-place disinfection process | en |
heal.abstract | A spectra-kinetic approach was applied for the simultaneous determination of peroxyacetic acid (PAA) and hydrogen peroxide with multiple linear regression (NILR) method, using the initial rates of their reaction with diphenylamine (DPA). The predictive ability of the MLR method is based on the slight kinetic differences of these analytes occur at two wavelengths when react with DPA as a common ligand. A stopped flow apparatus was used. and the time-resolved UV-vis spectra were measured with a coupled charge device (CCD) spectrophotometer. This novel instrumentation allowed to obtain high quality kinetic data at a maximum of many wavelengths simultaneously. The method was successfully applied to the simultaneous determination of these peroxides in residues from a disinfection process in a beer brewery. (C) 2004 Elsevier B.V. All rights reserved. | en |
heal.access | campus | - |
heal.fullTextAvailability | TRUE | - |
heal.identifier.primary | DOI 10.1016/j.aca.2004.07.010 | - |
heal.identifier.secondary | <Go to ISI>://000223869800017 | - |
heal.identifier.secondary | http://ac.els-cdn.com/S0003267004008475/1-s2.0-S0003267004008475-main.pdf?_tid=6f4ff39cc57fade2330f0fd4f8d624bf&acdnat=1335371044_854e2169165c57c838fde0d9c8d515dc | - |
heal.journalName | Analytica Chimica Acta | en |
heal.journalType | peer reviewed | - |
heal.language | en | - |
heal.publicationDate | 2004 | - |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας | el |
heal.type | journalArticle | - |
heal.type.el | Άρθρο Περιοδικού | el |
heal.type.en | Journal article | en |
Αρχεία
Φάκελος/Πακέτο αδειών
1 - 1 of 1
Φόρτωση...
- Ονομα:
- license.txt
- Μέγεθος:
- 1.74 KB
- Μορφότυπο:
- Item-specific license agreed upon to submission
- Περιγραφή: