Noise measurements on Si sensors

dc.contributor.authorEvangelou, I.en
dc.contributor.authorKokkas, P.en
dc.contributor.authorManthos, N.en
dc.contributor.authorProuskas, C.en
dc.contributor.authorTriantis, F.en
dc.contributor.authorTzoulis, N.en
dc.contributor.authorAspell, P.en
dc.contributor.authorBarney, D.en
dc.contributor.authorBloch, P.en
dc.contributor.authorKloukinas, K.en
dc.contributor.authorPeisert, A.en
dc.contributor.authorReynaud, S.en
dc.contributor.authorGo, A.en
dc.contributor.authorElsha, V.en
dc.contributor.authorZubarev, E.en
dc.contributor.authorCheremukhin, A.en
dc.contributor.authorZamiatin, N.en
dc.date.accessioned2015-11-24T18:39:53Z
dc.date.available2015-11-24T18:39:53Z
dc.identifier.issn0168-9002-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/17516
dc.rightsDefault Licence-
dc.subjectcmsen
dc.subjectpreshoweren
dc.subjectsilicon stripsen
dc.subjectnoiseen
dc.titleNoise measurements on Si sensorsen
heal.abstractDeveloping silicon strip sensors for the CMS Preshower detector we have noticed that some strips have a noise higher than the average and not correlated to a high leakage current. In order to investigate this effect we have developed a setup for noise measurement on wafers and diced sensors that does not require bonding. The set-up is based on the DeltaStream chip coupled to a probe card. We have tested 45 sensors and found that the strips with an above average noise have a higher relative current increase as a function of voltage, DeltaI/(IDeltaV). We also observed that, on these strips, the breakdown occurs within about 60 V from the voltage at which the noise is observed. We describe our measurement method and present the results. (C) 2002 Elsevier Science B.V. All rights reserved.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.secondary<Go to ISI>://000178895500004-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0168900202015565/1-s2.0-S0168900202015565-main.pdf?_tid=5a478c6cab89e09450156f1606a4df8f&acdnat=1334228577_71a572a2575cddc7c2fe95b225c8a6d7-
heal.journalNameNuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipmenten
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate2002-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών και Τεχνολογιών. Τμήμα Βιολογικών Εφαρμογών και Τεχνολογιώνel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: