Gas chromatographic determination of amino acids via one-step phase-transfer catalytic pentafluorobenzylation-preconcentration

dc.contributor.authorFiamegos, Y. C.en
dc.contributor.authorStalikas, C. D.en
dc.date.accessioned2015-11-24T16:38:20Z
dc.date.available2015-11-24T16:38:20Z
dc.identifier.issn0021-9673-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/8031
dc.rightsDefault Licence-
dc.subjectphase-transfer catalysisen
dc.subjectamino acidsen
dc.subjectalkaline hydrolysisen
dc.subjectgas chromatographyen
dc.subjectpentafluorobenzyl bromideen
dc.subjectionization mass-spectrometryen
dc.subjectperformance liquid-chromatographyen
dc.subjectchemical-ionizationen
dc.subjectcapillary-electrophoresisen
dc.subjectselective detectionen
dc.subjectquaternary ammoniumen
dc.subjectflow-injectionen
dc.subjectderivatizationen
dc.subjectderivativesen
dc.subjectsamplesen
dc.titleGas chromatographic determination of amino acids via one-step phase-transfer catalytic pentafluorobenzylation-preconcentrationen
heal.abstractThe gas chromatographic determination of amino acids via their simultaneous extraction, preconcentration and pentafluorobenzylation is reported. Using phase-transfer catalysis (PTC), the amino acids under study were transformed to their pentafluorobenzyl adducts. The method was tested for different catalysts and tetrabutylammonium bromide provided favorable features in comparison to the other PTCs. The derivatization procedure was optimized and the best reaction conditions are given. With the exception of arginine, 19 amino acids were converted to volatile derivatives and analyzed with GC/MS and GC/FID at low concentration levels with acceptable sensitivity and good reproducibility. The LODs were found to range from 0.7 to 2.3 mu M for the GC/MS analyses and from 1.7 to 6.9 mu M for GC/FID analyses. The method practicability and applicability were confirmed by the analysis of urine, fruit juice and wheat flour for the determination of the amino acids under study. Protein-bound amino acids were analyzed after an alkaline hydrolysis step with 5 M NaOH applying this method to wheat flour with an overall procedure duration less than 12 h. The optimized protocol was applied to these samples without any pretreatment and their amino acid concentrations were calculated from the appropriate calibration plots. (c) 2006 Elsevier B.V. All rights reserved.en
heal.accesscampus-
heal.fullTextAvailabilityTRUE-
heal.identifier.primaryDOI 10.1016/j.chroma.2006.01.074-
heal.identifier.secondary<Go to ISI>://000236439000009-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0021967306002068/1-s2.0-S0021967306002068-main.pdf?_tid=0db7af539555d361fc7a9efeea17daff&acdnat=1333040758_52d6b858b63b9c563f265f3aff27d348-
heal.journalNameJournal of Chromatography Aen
heal.journalTypepeer reviewed-
heal.languageen-
heal.publicationDate2006-
heal.publisherElsevieren
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.typejournalArticle-
heal.type.elΆρθρο Περιοδικούel
heal.type.enJournal articleen

Αρχεία

Φάκελος/Πακέτο αδειών

Προβολή: 1 - 1 of 1
Φόρτωση...
Μικρογραφία εικόνας
Ονομα:
license.txt
Μέγεθος:
1.74 KB
Μορφότυπο:
Item-specific license agreed upon to submission
Περιγραφή: